The PULS ML60.242 is a compact, industrial class DIN rail power supply designed for harsh environments where inrush current limitation and wide temperature capabilities are required. The ML60.242 features high immunity against electrical disturbances and operates in an extended temperature range to reliably function in even the most demanding environments. Standard features include low no-load losses, excellent partial load efficiency, and an operating temperature range compliant with the NEMA TS2 traffic standard.
Hardware
- Enclosure UL Compliant fully isolated plastic
- Enclosure Degree of ProtectionIP20
- Installation Method DIN RAIL (35MM)
- DIN Rail Mounting TS35/7.5 or TS35/15
- LED Indicators Output voltage status
- Dimensions 3.58" x 1.77" x 2.95"
- Product Weight 0.55 lb
Input Specifications
- Connector Type Screw Terminals
- Wire Gauge 10-20AWG
- Recommended Tightening Torque 9lb.in
- AC Voltage Range 85-264VAC
- Frequency Range 47-63Hz
- AC Input Current (Typ.) 0.66A/230VAC
1.05A/120VAC
- DC Voltage Range 88-375VAC
- DC Input Current (Typ.) 0.22A/110VAC
0.62A/110VAC
- Efficiency (Typ.) 90.4%
- Cold Start Inrush Current (Max.) 8A
- No Load Power Consumption < 0.85W
- Leakage Current < 0.85mA
Output Specifications
- Connector Type Screw Terminals
- Wire Gauge 10-20AWG
- Recommended Tightening Torque 9lb.in
- DC Voltage 24VDC
- Voltage Adjustable Range 24-28VDC
- Rated Current (Max.) 2.5A
- Current Range 0-2.5A
- Rated Power 60W
- Output Load Derating 1.5W/C° from 60° to 70°C
- Ripple and Noise (Max) 20mVp-p, 20Hz-20MHz
- Line Regulation 10mV
- Load Regulation 100mV
- Turn-on Overshoot (Max) 200mV
- Start-up Delay 90ms/ 230VAC
110ms / 120VAC
- Rise Time 60ms/230VAC
50ms/110VAC
- Hold Up Time 107ms/230VAC at full load
24ms/120VAC at full load
Protection Specifications
- Short Circuit/Overload
- Overload Protection TypeElectronically limited
Output voltage dips during overload
- Over Voltage
- Rated Voltage 31-32.5VDC
- Over Voltage Protection Type Shutdown output voltage, re-power on to recover
- Input Transient Protection Metal Oxide Varistor (MOV)
- Internal Input Fuse3.15A/250VAC
Saftey and Dielectric Strength Specifications
- Input / Output SeparationSELV per IEC/EN 60950-1, PELV per IEC/EN 60204-1,
EN 50178, IEC 62103, IEC60364-4-41
- Isolation Resistance> 5Mohm
Input to output, 500VDC
- Dielectric Withstanding Voltage
- Input to Output4000VAC
- Input to Earth Ground2500VAC
- Output to Earth Ground2000VAC
- Input Transient Protection Metal Oxide Varistor (MOV)
- Internal Input Fuse3.15A/250VAC
Environmental Specifications
- Air temperature
- System On -40 to 74° C
- System Off -40 to 85° C
- Operating Humidity (non-condensing) 5% to 95% r.H.
- Vibration 2 –17.8Hz: ±1.6mm
17.8 – 500Hz: 2g 2 hours/ axis
- Shock15g 6ms, 10g 11ms
3 bumps / direction, 18 bumps in total
- Altitude0 to 6000m
- Altitude De-rating4W/1000m or
5°C/1000m from 2000m to 6000m
- MTBF (Mean Time Between Failures)367.1 Years
Export Information
- Packaged Shipping Weight0.75lbs
- Package Dimensions5.9" x 2.4" x 5.5"
- UPC Code8-75404-00160-9
- ECCN 4A994
- Schedule B Number 8504.40.6007
Regulatory Approvals
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
- Wide operating temperature range for extreme and outdoor applications
- Compact DIN rail design
- 100-240V input range
- Adjustable output voltage
- Up to 90.4% efficiency
- NEC Class 2/LPS Compliant
- No load power consumption < 0.75W
|
|
|
|
|
|
|