Optical isolation protects your devices from transient surges and ground loops on your data line. Model 485OPDR repeater adds 4,000 feet (1.2 km) and another 32 nodes to an RS-485 data circuit. By configuring one side as RS-422 and the other as RS-485, Model 485OPDR can act as a converter to allow your four wire RS-422 equipment to talk to a 2-wire RS-485 device. Requires an external power supply not included.
General Features
- Wide temperature ranges (-40 to 80º C)
- Modbus ASCII or RTU compatible
- Automatic Send Data Control
- 600 W surge suppression
- DIN rail mount
Standard model -
485OPDR - features include 10-30 VDC operation, 2-way isolation, 2000V
input/output, CE approved, UL Recognized.
Premium model -
485OPDRi - features include 10-48 VDC operation, triple isolation, 2000V
input/output power supply, UL Class 1 Div 2
approval,
cUL approval,
CE approved.
Heavy Industrial / Power Utility Version -
485OPDRI-PH - features include IEC 61850-3 / IEEE 1613, 2KV isolation, -40 to 85° C, UL Class 1 Division 2.