Comtrol’s IO-Link Master combines the benefits of the IO-Link standard with the EtherNet/IP™ and Modbus TCP protocols. The IO-Link Master effectively shields the PLC programmers from the IO-Link complexities by handling those complexities itself. The result is simplified EtherNet/IP™ and Modbus TCP interfaces, which decreases system development time and installation efforts.
This IO-Link Master easily installs on a standard DIN rail and incorporates two Fast Ethernet ports, eight pluggable/removable push-in plug IO-Link ports. This product is designed with industrial grade components and redundant power inputs to make it exceptionally reliable for critical applications. The IO-Link Master is easily integrated into a system network and is compatible with existing and new industrial Ethernet environments.
Hardware
- Network Interface10/100BASE-TX
- EnclosurePolyamide, UL94V-0
- Ingress Protection RatingIP20
- Installation and Grounding MethodDIN Rail
- Connectors (PWR & IO-Link)Pluggable Push-In screwless terminal plugs
- Connection MethodPush-In spring screwless terminals
- Connectors (Ethernet)RJ45
- Network ProtocolsEtherNet/IP & Modbus TCP
- Channels8 x IO-Link / Digital I/O (configurable)
8 x Digital Input DI
2 x Ethernet
- LED IndicatorsModule Status, Network Status, IO-Link, DI, Ethernet Link & Activity
- Dimensions (Width x Height x Depth)1.78” x 4.65” x 4.5”
45 mm x 118 mm x 114 mm
- Product Weight8.8 oz
249.5 g
Electrical Specifications
- DC Input Voltage Range18 VDC – 30 VDC
- Current Consumption with sensors3.7 A max. at 24VDC
- Current Consumption (system electronics)155 mA at 24VDC
- Power Consumption (system electronics)3.75 W
- Power Input Connector1
Environmental Specifications
- Operating Temperature-40°C to +70°C
- Storage Temperature-40°C to +85°C
- Operating Humidity (Non-Condensing)10% to 95%
- Storage Humidity (Non-Condensing)10% to 95%
- Shock / VibrationsEN60068-2-6
EN60068-2-27
- Environmental / Mechanical ApprovalsIEC 61131-2
IEC 60529
Ethernet Interface Specifications
- Connector TypeRJ45
- Number of Ports2
- Ethernet Specification10/100BASE-TX
- StandardsIEEE 802.3: 10BASE-T
IEEE 802.3u: 100BASE-TX
- Auto-MD/MDI-XYes
- Auto-NegotiationYes
- Link Distance100 m
- Cable TypesUnshielded or Shielded twisted pair
- IPv4 AddressingYes
IO-Link Ports Specifications
- Number of Connectors8 (PORT 1 – 8)
- Number of Channels8 x IO-Link / Digital I/O (configurable)
8 x DI
- IO-Link VersionSupports V1.0 and V1.1
- Port PinoutPin 1 – L+
Pin 2 – L-
Pin 3 – DI
Pin 4 – C/Q (configurable)
- Configurations per Port
- Pin 4 (configurable):IO-Link
DI (SIO mode)
DO (SIO mode)
- Pin 3: DI
- Output Current L+/L- (Pins 1 & 3)200 mA
- Output Current C/Q (Pin 4)200 mA
- Output Current per Master3.2 A (max.)
- IO-Link Mode Transfer Rates4.8K (COM1)
38.4K (COM2)
230.4K (COM3)
- Baud Rate RecognitionAutomatic
- Cable Length20 m (max.)
IO-Link Ports – Digital Input SIO Mode (Port Pin 4)
- Input CharacteristicsIEC 61131-2 Type 1 and Type 3 Compliant
- Sensor supply current (L+/L-)200 mA
- Sensor Supply current per Master1.6 A (max.)
- Input ThresholdHigh: 10.5 – 13.0V
Low: 8.0 – 11.5V
- Cable length (max.)30 m
IO-Link Ports – Digital Output SIO Mode (Port Pin 4)
- Typical Output Voltage24 VDC
- Output Current (max.)200 mA
- Output Current per Master1.6 A (max.)
- ProtectionOverload and short circuit protection
- Output FunctionPNP/NPN (Push-Pull)
- Cable length (maximum)30 m
IO-Link Ports – Digital Input (Port Pin 3; dedicated)
- Input CharacteristicsIEC 61131-2 Type 1 and Type 3 Compliant
- Typical Input Current3 mA
- Input ThresholdHigh: 6.8 – 8.0V< br/>Low: 5.2 – 6.4V
- Reverse Polarity ProtectedYes (-40V to +40V)
- Cable length (maximum)30 m
EtherNet/IP Specifications
- Supported PLCs
- Including but not limited to:Control Logix
Compact Logix
RSLogix
SLC 500
PLC5
MicroLogix
- Other Class 1 or Class 3 EtherNet/IP PLCs may be supported
- ISDU Read & WritesUp to 40 individual commands in one EtherNet/IP message
- ISDU CommandsSelectable byte swapping (none, 16-bit, or 32-bit)
Selectable payload sizes (4 to 232 bytes)
ISDU block index
ISDU sub-index
Length of read or write
Data payload
- Web Page Configuration
- Provides the following capabilities:Port configuration for ISDU Data, Process Data, Transfer Mode, Read/Write, Write PDI to Tag/File, and Read PDO from Tag/File.
EtherNet/IP configuration:
• Time to Live (TTL) Network Value
• Multicast IP Address Allocation Control
• User-Defined Number of Multicast IP Addresses
• User-Defined Multicast Starting IP Address
- Session Encapsulation Timeout
- DiagnosticsYes
- Electronic Data Sheet (EDS)Yes
- Sample PLC ProgramsYes
Modbus TCP Specifications
- Supported Controllers (Modbus TCP Masters)PLC
HMI
SCADA
OPC Server
- Supported ClientsAny Modbus TCP Client
Applications on phones/tables
- Web Page ConfigurationPort configuration for ISDU Response Timeout, Process Data, and Transfer Mode.
- DiagnosticsYes
Additional Features
- ConfigurationEmbedded web interface, IO-Link, EtherNet/IP, and Modbus TCP
- Data StorageAutomatic or Manual - Upload and/or Download
- Device ValidationYes
- Data ValidationYes
- DiagnosticsIO-Link, EtherNet/IP, and Modbus TCP
- Powerful Web Interface
- Provides the following capabilities:Firmware upgradable
Password protected with Admin, Operator, and User accounts
ISDU batch handling
Load IODD files to configure the IO-Link device
IODD Handler parses xml files making them readable and configurable
Save/Load Configuration Files
Log files
- Upgradable FirmwareYes (Web page or using PortVision DX)
- Remote ParameterizationYes
- Mobile App SupportSimplify monitoring of control system Process and Service Data using simple standard clients available for free in Google Play and Apple App Store
Export Information
- Packaged Shipping Weight0.85 lbs.
385.5 g
- Package Dimensions (L x W x H)5.7” x 5.7 ” x 3.4”
145mm x 145mm x 86.4mm
- UPC Code7-56727-99669-6
- Country of OriginUSA
- ECCN5A992
- Schedule B Number8517.62.0050
Regulatory Approvals
- ImmunityEuropean Standard EN 61000-6-2
International Standard IEC 61000-6-2
- EN/IEC 61131-2 and EN/IEC 61131-9IEC 1000-4-2/EN 61000-4-2: Electrostatic Discharge (ESD)
IEC 1000-4-3/EN 61000-4-3: Radiated, Radio-Frequency (RF)
IEC 1000-4-4/EN 61000-4-4: Fast Transient/Burst
IEC 1000-4-5/EN 61000-4-5: Surge
IEC 1000-4-6/EN 61000-4-6: Conducted disturbance
IEC 1000-4-8/EN 61000-4-8: Magnetic field
IEC 1000-4-11/EN 61000-4-11: Dips and Voltage Variations
- EmissionEuropean Standard EN 61000-6-4
International Standard IEC 61000-6-4
AS/NZS CISPR-11
- FCC Part15 Subpart BClass A limit
Canadian EMC requirements ICES-001
- SafetyCSA C22.2 No. 61010-1-12 / CSA C22.2 No. 61010-1-201
UL 61010-1 / UL 61010-1-201
UL File # E360395
- VibrationEN 60068-2-6/ IEC 60068-2-6
- Mechanical ShockEN 60068-2-27/ IEC 60068-2-27
- Environmental / Mechanical Test ApprovalsIEC 61131-2
IEC 60529
- Ingress Protection RatingIngress Protection rating IP20 (IEC 60529)
- OtherThe components of this product comply with the requirements of the EMC/EMI Directive 2014/30/EU, Directive 2011/65/EU on the Restriction of the use of certain Hazardous Substances (RoHS2).
- Regulatory Approval Symbols
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
- Eight port IO-Link Master to EtherNet/IP™ with pluggable/removable push-in plug connectors for IO-Link and Power
- IP20 DIN rail mount enclosure
- Dual Ethernet ports
- Additional digital input on every port
- MultiLink™ – Simultaneously provides IO-Link device access to multiple controllers
- EtherNet/IP™ Class 1 (Implicit) and Class 3 (Explicit) interfaces
- EtherNet/IP™ and Modbus TCP access to IO-Link process, event, and service data
- HMI, SCADA, and PLC access to IO-Link ISDU blocks without complex programming
- EDS files and sample programs
- Convenient EtherNet/IP Write-to-Tag/File, Read-from-Tag/File data exchange option
- Powerful web GUI for configuration and diagnostics, including: IO-Link device management using the IO-Link device manufacturers IODD file for easy device configuration, Automatic data storage (upload and download), Manual data storage (upload and download), Device validation, and Data validation.
- Works with PortVision DX - a discovery management application
- LEDs for device, network, and port status
- Wide operating temperature (-40° to +70°C)
- IO-Link V1.0 and V1.1 compatibility
- IO-Link COM1, COM2 and COM3 (230K baud rate) support
- Accredited IO-Link Test Center
|
|
|
|
|
|
|