The ED3541 Ethernet extender allows the extension of IP services beyond normal Ethernet distance limitations without changing cables, breaking the 100-meter Ethernet barrier.
The ED3541’s hardened design features high shock and vibration, electrical noise immunity, a wide operating temperature range from -40 to 75°C, and ruggedized aluminum housing. The ED3541 is the ideal Ethernet extender for environments where connectivity is crucial.
Technology
Standards
- • IEEE 802.3 10BASE-T
- • IEEE 802.3u 100BASE-TX
- • IEEE 802.3x full duplex and flow control
Processing Type
- • Half-duplex back-pressure and IEEE 802.3x Full-duplex flow control
- • Auto Negotiation
- • Auto MDI/MDIX
Power
Input Voltage
- • 12-48VDC (Terminal Block)
Power Consumption
- • 4.56W max. 0.38A@12VDC, 0.07A@48VDC
Protection
- • Over current protection
- • Reverse polarity protection
Mechanical
Casing
Dimensions
- • 42 x 90 x 100mm (W x D x H)
(1.65" x 3.54" x 3.94")
Weight
Installation
- • DIN-Rail (Top hat type 35mm) mounting
Interface
Ethernet Port
- • Port: One RJ-45 port
- • Speed: 10/100Mbps
- • Distance: 100 meters (328ft.)
- • Cable: 10BASE-T: UTP CAT. 3, 4, 5 (2-pair wire), 100BASE-TX: UTP CAT. 5 (4-pair wire)
Ethernet Extender Port
- • Port: One RJ-11/Terminal Block port
- • Speed: Up to 100Mbps
- • Distance: 2200 meters (7217ft.)
- • Cable: Telephone wire 24AWG (0.5mm diameter, 1-pair wire) or larger
DIP Switch
- • DIP 1 Site: Auto/Loc
- • DIP 2 LDR: On/Off
LED Indicators
- • Per Unit: Power 1, Power 2
- • Per 10/100TX Port: Link/Activity, Full-duplex
- • Line Speed: 100/80/60/40/20Mbps and Link below 20Mbps
► Speed/Distance Reference
Distance
|
Data rate
|
200m
|
100Mbps
|
400m
|
80Mbps
|
600m
|
60Mbps
|
800m
|
40Mbps
|
...
|
...
|
2200m
|
1Mbps
|
- • All speed selections are Symmetrical on the DSL and Fullduplex on the Ethernet
- • The data rate will vary according to line quality
Environment
Operating Temperature
- • -40 to 75°C (-40 to 167°F)
Tested @ -40 to 85°C (-40 to 185°F)
Storage Temperature
- • -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
- • 5% to 95% (non-condensing)
Regulatory Approvals
ISO
- • Manufactured in an ISO 9001 facility
Safety
- UL 60950-1
- EN 60950-1
- IEC 60950-1
- ISA 12.12.01
- • Class 1, Division 2 group A, B, C &D for hazardous locations
EMI
- FCC Part 15B Class A
- VCCI Class A
- EN 61000-6-4
EMS
- EN 61000-6-2
- • EN 61000-4-2 (ESD Standards)
- • EN 61000-4-3 (Radiated RFI Standards)
- • EN 61000-4-4 (Burst Standards)
- • EN 61000-4-5 (Surge Standards)
- • EN 61000-4-6 (Induced RFI Standards)
- • EN 61000-4-8 (Magnetic Field Standards)
Environmental Test Compliance
- IEC 60068-2-6 Fc (Vibration Resistance)
- IEC 60068-2-27 Ea (Shock)
- FED STD 101C Method 5007.1 (Free fall w/package)