Moxa 8 port IEC 61850-3 rugged 3-in-1 device server + managed Ethernet switch w/(8) RS232/422/485 ports [multimode ST connectors on the serial ports], (2) 10/100M RJ45 [1588v2], (1) 2 port 10/100M Ethernet RJ45 module & 110/220VDC/VAC (XT)
Our Price: $3,095.24
Contact Us for Partner Pricing. (more info)



Availability:: Usually Ships in 24 Hours; However, Due To Shortages Contact Sales to Verify
Product Code: NPORTS9650I-8F-2HV-E-T

Description Drivers & Downloads
 
Overview
The NPort S9650I Series 8/16-port RS-232/422/485 device servers, which come with a built-in full-function managed Ethernet switch, are designed specifically for the harsh environmental conditions found in electrical substations. With both fiber and wire Ethernet ports supported, the combination of a device service and Ethernet switch gives users the ability to easily install, manage, and maintain the NPort S9650I itself, as well as attached serial devices.

Electromagnetic Compatibility for Harsh Substation Environments
The NPort S9000 Series supports a high level of surge protection to prevent damage from the types of power surges and EMI one finds in electrical substations and industrial automation applications. Combined with a -40 to 85°C operating temperature range and galvanized steel housing, the NPort S9000 is suitable for a wide range of industrial environoments. Another plus is the NPort S9000’s dual power supplies, which provide both redundancy and a wide range of voltage inputs. The HV models accept a power input of 88 to 300 VDC and 85 to 264 VAC.

Power SCADA with IEC 61850 MMS for Easy Maintenance
The current trend in power SCADA applications is to control and monitor both IT devices (switches, routers, etc.) and IEDs (sensors, actuators, etc.) with the MMS protocol. Contrast this with the more traditional management approach of using SNMP for IT devices and MMS for IEDs. In fact, SIs may even need to manage a variety of legacy devices that use proprietary communications protocols. The NPort S9000 device servers are the world’s first device servers to integrate MMS into an IT-type device designed specifically for power SCADA applications. The NPort S9000 even supports using MMS to monitor serial legacy devices.

Supports Modbus/DNP3 Protocol Gateway
The NPort S9000 Series provides maximum flexibility for integrating industrial Modbus/DNP3 networks of all types and sizes. The NPort S9000 is designed to integrate Modbus TCP, ASCII, and RTU devices in almost any master/slave combination, including simultaneous serial and Ethernet masters. The NPort S9000 device servers also support protocol conversion between DNP3 serial and DNP3 IP. All models are ruggedly constructed and are DIN-rail mountable.

Cybersecurity Features Based on IEC-62443/NERC CIP
The NPort S9650I Series has security features based on IEEE 62443/ NERC CIP to provide a high level of cybersecurity. Protecting missioncritical networks from cyberattacks is a high priority for industrial automation applications, which can suffer large losses due to extended network downtime.

Supports IEEE 1588v2 and IRIG-B Time Synchronization Functions
The NPort S9650I Series, which has a modular design that supports IEEE 1588 and IRIG-B time synchronizaion, is able to interconnect and synchronize multiple types of intelligent electronic devices (IEDs) that use different communication protocols. The time source is provided via IEEE 1588 v2 and converted to IRIG-B for distribution to the IEDs via the serial ports or via a dedicated IRIG-B BNC connector.

Ring Redundancy at the Device Level
Device-level communication networks for industrial automation are very critical since they are used to control and monitor device processes. The reliability of these communications depends on ring redundancy at the device level, which is designed to provide fast network fault detection and reconfiguration to support the most demanding control applications. The NPort S9000 Series integrates a full-function NPort device server with an industrial switch to carry serial and Ethernet devices at the same time. In addition, the NPort S9000 can also achieve ring redundancy with standard STP/RSTP and Moxa’s proprietary Turbo Ring or Turbo Chain 2 redundancy protocols. This all-in-one design can be used to optimize and simplify your device network and enhance reliability.
Features

General Specifications
Port Summary
Serial Ports 8/16 RS-232/422/485 ports
Ethernet Switch Ports 2 built-in RJ45 Ethernet ports. Add 2 additional Ethernet ports with optional expansion modules:• Option 1: Expansion module with 2 RJ45 Ethernet ports
• Option 2: Expansion module with 2 fiber Ethernet ports
• Option 3: Expansion module with BNC connectors for IRIG-B time sync
Magnetic Isolation Protection 1.5 kV built in
Console Ports 1 (10-pin RJ45 connector)
Physical Characteristics
Housing Metal
Weight 5.15 kg (11.35 lb)
Dimensions 457 x 32 x 330 mm (18.00 x 1.25 x 12.99 in)
Environmental Limits
Operating Temperature -40 to 85°C (-40 to 185°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
Power Requirements
Input Voltage 110/220 VAC/VDC (100 to 240 VAC, 100 to 250 VDC)
Input Current 0.65 A @ 100 VAC, 0.47 A @ 100 VDC
Standards and Certifications
Safety UL 61010-2-201
EMC EN 61000-6-2/61000-6-4
EMI CISPR 22, FCC Part 15B Class A
EMS IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m
IEC 61000-4-8 PFMF
IEC 61000-4-11 DIPs
Electrical Substation IEC 61850-3, IEEE 1613
Warranty
Warranty Period 5 years
Details See www.moxa.com/warranty
Device Server Specifications
Serial Interface
Number of Ports 8 or 16
Serial Standards RS-232/422/485
Connector DB9 male, DB9 female, multi-mode fiber (ST)
Serial Line Protection 2 kV isolation protection
RS-485 Data Direction Control ADDC® (Automatic Data Direction Control)
Terminator for RS-485 120 Ω
Console Port Dedicated RS-232 console port (10-pin RJ45)
Serial Communication Parameters
Data Bits 5, 6, 7, 8
Stop Bits 1, 1.5, 2
Parity None, Even, Odd, Space, Mark
Flow Control RTS/CTS and XON/XOFF
Baudrate 50 bps to 921.6 Kbps
Serial Signals
RS-232 TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422 Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w Data+, Data-, GND
Software
Configuration Options Command Line Interface (CLI) through Serial/Telnet/SSH, Web Console (HTTP/HTTPS), Windows Utility
Windows Real COM Drivers Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1/10 (x86/x64), Windows 2008 R2/2012/2012 R2 (x64), Windows Embedded CE 5.0/6.0, Windows XP Embedded
Fixed TTY Drivers SCO Unix, SCO OpenServer, UnixWare 7, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i, Mac OS X
Linux Real TTY Drivers Linux 2.4.x, 2.6.x, 3.x, 4.x
Android API Android 3.1.x and later
Operation Modes Real COM, TCP Server, TCP Client, UDP, RFC2217, Modbus, DNP3, DNP3 Raw Socket
Management SNMP MIB-II, IEC 61850 MMS
Reliability
Alert Tools Built-in buzzer and RTC (real-time clock)
Automatic Reboot Trigger Built-in WDT (watchdog timer)
MTBF (mean time between failures)
Time NPort S9650I-8-2HV-E-T: 224,670 hrs
NPort S9650I-8-2HV-MSC-T: 220,944 hrs
NPort S9650I-8-2HV-SSC-T: 220,944 hrs
NPort S9650I-8B-2HV-IRIG-T: 213,025 hrs
NPort S9650I-8F-2HV-E-T: 311,734 hrs
NPort S9650I-8F-2HV-MSC-T: 304,587 hrs
NPort S9650I-8F-2HV-SSC-T: 304,587 hrs
NPort S9650I-16-2HV-E-T: 158,816 hrs
NPort S9650I-16-2HV-MSC-T: 156,949 hrs
NPort S9650I-16-2HV-SSC-T: 156,949 hrs
NPort S9650I-16B-2HV-IRIG-T: 157,770 hrs
NPort S9650I-16F-2HV-E-T: 261,817 hrs
NPort S9650I-16F-2HV-MSC-T: 256,761 hrs
NPort S9650I-16F-2HV-SSC-T: 256,761 hrs
Standard Telcordia (Bellcore) Standard TR/SR
Ethernet Switch Specifications
Ethernet Interface
Standards IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3x for Flow Control
IEEE 802.1D for Spanning Tree Protocol
IEEE 802.1w for Rapid STP
IEEE 802.1Q for VLAN Tagging
IEEE 802.1p for Class of Service
IEEE 802.1x for Authentication
IEEE 802.3ad for Port Trunk with LACP
Network Protocols ICMP, IPv4, TCP, UDP, ARP, Telnet, DNS, HTTP, SMTP, SNTP, IGMPv1/v2, GVRP, SNMPv1/v2c/v3, DHCP Server/Client, DHCP Option 82, BootP, TFTP, SNTP, SMTP, RARP, GMRP, LACP, RMON
MIB MIB-II, Ethernet-Like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9
Flow Control IEEE 802.3x flow control, back pressure flow control interface
Switch Properties
Priority Queues 4
Max. Number of Available VLANs 64
VLAN ID Range VID 1 to 4094
IGMP Groups 256
Cybersecurity Ready for NERC CIP compliance system development
• Supports IEC 62443
• Supports port access control list: MAC, 802.1x authentication
• Supports RADIUS, TACACS+
• Supports Syslog for system/event
• Pin Assignment
Optical Fiber Interface
Table
Switch Interface
RJ45 Ports 10/100BaseT(X) auto negotiation speed, F/H duplex mode, and auto MDI/MDI-X connection
Alarm Contact 1 relay output with current carrying capacity of 1 A @ 24 VDC