EtherWAN’s PD3041 Hardened Surge Protection Device shields DSL equipment from dangerous power surges, ground loops, and electrical discharges caused by faulty wiring or lightning. With full wire-to-wire and wire-to-earth surge protection, the PD3041 is ideal for use in areas that have unstable supplies of electricity, and on sites that have excessive amounts of electromagnetic interference. Applications include outdoor IP cameras and access points, as well as rooftop networking cabinets.
Electrical
Maximum continuous operating voltage UC
Maximum continuous voltage UC (wire-wire)
Maximum continuous voltage UC (wire-ground)
Nominal current IN
Operating effective current IC at UC
Residual current IPE
Nominal discharge surge current In (8/20) μs
Nominal discharge surge current In (8/20) μs
Total surge current (8/20) μs
Nominal pulse current Ian (10/1000) μs
Nominal pulse current Ian (10/1000) μs
Nominal pulse current Ian (10/700) μs
Nominal pulse current Ian (10/700) μs
Output voltage limitation at 1 kV/μs (Core-Core) spike
Output voltage limitation at 1 kV/μs (Core-Earth) spike
Residual voltage at In, (conductor-conductor)
Residual voltage at In, (conductor-ground)
Voltage protection level UP (Core-Core)
- • ≤ 300 V (B2 – 100A)
- • ≤ 300 V (C1 – 500A)
- • ≤ 300 V (C2 – 5kA)
Voltage protection level UP (Core-Earth)
- • ≤ 300 V (B2 – 100A)
- • ≤ 300 V (C1 – 500A)
- • ≤ 300 V (C2 – 5kA)
Response time tA (Core-Core)
Response time tA
Input attenuation aE, sym.
- • Typ. 0.5 dB (≤ 5 MHz)
- • Typ. 0.3 dB (≤ 8 MHz / 150Ω)
- • Typ. 0.3 dB (≤ 2.5 MHz / 600Ω)
Near-end crosstalk attenuation
- • ≤ 35 dB (At 250 MHz / 100 Ω)
Cut-off frequency fg (3 dB), sym. in 100 Ohm system
Resistance in series
Surge carrying capacity in acc. with IEC 61643-21
- (Core-Core)
- • B2 (4kV / 100A)
- • C1 (1kV / 500A)
- • C2 (10kV / 5kA) (Terminal block)
- • C2 (6kV / 3kA) (RJ11)
Surge carrying capacity in acc. with IEC 61643-21
- (Core-Earth)
- • B2 (4kV / 100A)
- • C1 (1kV / 500A)
- • C2 (10kV / 5 kA) (Terminal block)
- • C2 (6kV / 3kA) (RJ11)
- • D1 (1 kA)
Mechanical
Casing
Dimensions
- • 62.5mm (W) x 100mm (H) x 30mm (D)
(2.5”(W) x 3.8”(H) x 1.18”(D))
Weight
Installation
- • RJ11 connector/ Terminal Block
Environment
Operating Temperature
- • -40°C to 75°C (-40°F to 167°F)
Storage Temperature
- • -40°C to 85°C (-40°F to 185°F)
Humidity
- • 5% to 95%, non-condensation
Regulatory Approvals
ISO
- • Manufactured in an ISO9001 facility
EMI
- • CE
- • FCC Part 15 Class B
- • VCCI
TUV
UL
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
- Provides pair-to-pair protection through RJ11 connector & terminal block
- Can be installed in control cabinet
|
|
|
|
|
|
|