The PTC-101 Ethernet-to-fiber media converters convert from 10/100BaseT(X) to 100BaseFX. Models are available with either SC, ST, or LC connectors. The PTC-101 converters eliminate the need for additional wiring, and support IEEE 802.3 and IEEE 802.3u/x protocols with 10/100M, full/half-duplex, and MDI/MDI-X auto-sensing to provide a total solution for your industrial Ethernet networks. The PTC-101 is compliant with the essential sections of EN 50155, covering operating temperature, power input voltage, surge, ESD and vibration.
Technology
|
Standards
|
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X), 100BaseFX
|
• Interface
|
RJ45/M12 Ports
|
10/100BaseT(X)
|
Fiber Ports
|
100BaseFX (SC/ST/LC connectors)
|
LED Indicators
|
PWR1, PWR2, Fiber Link, 10/100M (TP port)
|
DIP Switches
|
|
Alarm Contact
|
One relay output with current carrying capacity of 1 A @ 24 VDC (LV model only)
|
• Optical Fiber
|
Table
|
|
• Physical Characteristics
|
Housing
|
Metal, IP30 protection
|
Dimensions
|
152.15 x 123.46 x 66.65 mm (5.99 x 4.86 x 2.62 in)
|
Weight
|
Product only: 690 g
Packaged: 875 g
|
• Environmental Limits
|
Operating Temperature
|
-40 to 85°C (-40 to 185°F)
|
Storage Temperature
|
-40 to 85°C (-40 to 185°F)
|
Ambient Relative Humidity
|
5 to 95% (non-condensing)
|
Conformal Coating
|
Available upon request
|
• Power Requirements
|
Input Voltage
|
|
Note
|
LV-DC compliant with EN 50155 on 48VDC
HV-DC compliant with EN 50155 on 110VDC
|
Connection
|
Removable terminal block
|
Overload Current Protection
|
1.6 A (protects against two signals shorted together)
|
Reverse Polarity Protection
|
Protects against V+/V- reversal
|
• Standards and Certifications
|
Safety
|
UL 60950-1
|
EMC
|
CE, FCC
|
EMI
|
FCC Part 15 Subpart B Class A, EN 55022 Class A
|
EMS
|
EN 61000-4-2 (ESD) Level 4,
EN 61000-4-3 (RS) Level 3, EN 61000-4-4 (EFT) Level 4, EN 61000-4-5 (Surge) Level 4, EN 61000-4-6 (CS) Level 3, EN 61000-4-8 (PFMF) Level 5, EN 61000-4-11
|
Power Automation
|
IEC 61850-3, IEEE 1613
|
Rail Traffic
|
EN 50155, EN 50121-4
|
Freefall
|
IEC 60068-2-32
|
Vibration
|
IEC-61850-3, IEC-60870-2-2, EN 50125-3
|
Green Product
|
RoHS, CRoHS, WEEE
|
Note
|
Refer to the “Environmental Type Tests” table below for more detailed information.
|
• MTBF (mean time between failures)
|
Time
|
1,211,613 hrs
|
Database
|
Telcordia (Bellcore), GB
|
• Warranty
|
Warranty Period
|
5 years
|
Details
|
See www.moxa.com/warranty
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
- 10/100BaseT(X) auto-negotiation and auto-MDI/MDI-X
- Link Fault Pass-Through (LFP)
- Power failure alarm by relay output (LV model only)
- -40 to 85°C operating temperature range
- Redundant dual DC power inputs (LV model only)
- Integrated high-reliability power supply eliminates the need for external power transformer
- Compliant with EN 50121-4 and essential sections of EN 50155
|
|
|
|
|
|
|